Hysol ®9436 
You may print this page for your file
Epoxy Adhesive 

Description

Hysol 9436 is an unfilled two part room temperature curing epoxy adhesive with excellent strength retention at elevated temperatures. It consists of a liquid resin and curing agent. Hysol 9436 yields rigid bonds that are resistant to salt spray and humidity exposure. This adhesive can also be used for laminating and for potting small assemblies.

Features
Excellent Tensile Sheer Strength                              High Temperature Resistant
Outstanding Environmental Resistance                 Low Viscosity - pourable
Room Temperature Curing

Typical Properties
                                                        Part A                                       Part B                                            Mixed
Color                                               Amber                                     Green                                             Pale Green
Viscosity, cps,                                 40,000                                       1000-3000                                     11,000
Brookfield HBT (Spdl)                 4 @ 20 rpm                              1 @ 20 rpm                                  3 @ 20 rpm
Specific Gravity                               1.22                                           0.95                                               1.10
Pounds per gallon                         10.5                                            8.0                                                 9.2

Handling
Mixing: This product requires mixing two components together just prior to the application. Complete mixing is necessary. The temperature of the separate components prior to mixing is not critical, but they should be at room temperature.
                                                                
Part A                                           Part B
By weight                                                  100                                                 58  
By volume                                                 43                                                    -
Pot life, (250 grams)                                                  45 minutes
Peak Exotherm, (250 grams)                                    525 @ 55
°F

Application
Mixing – Bulk: Combine Part A (resin) and Part B (hardener) in the correct ratio and mix thoroughly. This is important! Heat build-up during or after mixing is normal. Do not mix quantities greater than two pounds as dangerous heat build-up can occur. Mixing smaller quantities will minimize the heat build-up.

Application: Bonding surfaces should be clean and dry. For optimum surface preparation, consult Dexter's bulletin "Preparing the Surface for Adhesive Bonding". Once the adhesive is applied, the boned parts should beheld in contact until the part has developed handling strength. It is not necessary to clamp the parts unless movement during curing is likely.

Cure: Hysol 9436 can be cured for 5 days at room temperature. Curing temperatures up to 200°F can be used to reduce cure time. For example, 1 hour at 180°F will give complete cure.

Clean up: It is important to remove excess adhesive from the work area and application equipment before it hardens. Many  common solvents and citrus cleaners are suitable for removing uncured adhesive. Consult with your supplier's information pertaining to the safe and proper use of solvents.

Performance
Tensile Lap Shear Strength: (tested per ASTM D1002 after curing for five days at 75oF on 1 x 0.5 overlap specimens)
Substrate                                                Test Temperature oF                             Tensile Lap Sheer Strength, psi
Etched Aluminum                                                77                                                                  2100
                                                                              -67                                                                  1800
                                                                               180                                                                1850
                                                                               300                                                                 900                               Degreased Aluminum                                          77                                                                   900  
FRP (1" overlap)                                                    77                                                                   900
Graphite-Epoxy Laminate                                    77                                                                   3300
Etched Aluminum after
Environmental Exposure:
30 day salt spray                                                     77                                                                   1950
30 day 120°F, @ 100%                                          77                                                                   1600
relative humidity
7 day @ 77
°F hydraulic oil                                     77                                                                   3000

Bulk Properties
Tensile properties tested at room temperature on 0.125-inch castings per ASTM D 638.
Tensile Strength, psi                                                  5,900
Tensile Modulus, psi                                                 370,000
Elongation at break, %                                              2.4
Shore D hardness                                                     80

Technical Consultation Service
Our technical staff and representative are ready to assist in solving any special bonding requirements. You are invited to take advantage of our extensive experience, laboratory services and trained field service staff. Call 800.767.8786 now and let us help you with your adhesive needs.

___________________________________________________________________________

  For additional information or distributor locations, please contact:
Manufacturing & Sales European Sales Far East Sales
Tel: 800.767.8786 Tel: 161.946.2000 Tel: 065.862.0228
Fax: 603.474.5545 Fax: 161.946.2001 Fax: 065.861.8850
___________________________________________________________________________

DISCLAIMER:
The information supplied in this document is for guidance only and should not be construed as a warranty.  All implied warranties are expressly disclaimed.  Including without limitation any warranty of merchantability and fitness for use: All users of the materials are responsible for assuring that it is suitable for their needs, environment and use.  All data is subject to change as Dexter deems appropriate.

Users should review the Material Safety Data Sheet (MSDS) and product label for the material to determine possible health hazards, appropriate engineering controls and precautions to be observed in using the material.  Copies of the MSDS and label are available upon request.
 

For more information or to order contact the Glu Guru™ at 1-800-323-5158
or
Email mike@on-hand.com